Zusammenfassung der Projektergebnisse

The overall goal of the NeuroTMR project was to contribute to the understanding of the mechanisms of neuronal information transmission by developing and applying a new generation of implantable magnetic field sensors. Here, the key advantage of using magnetic sensors rather than electrodes is that the magnetic fields pass through tissues without significant distortion and allow for contactless detection that avoids problems related to electrode degradation. Especially the latter property makes the measurement of neural information using magnetic field sensors particularly attractive for the design of durable implants for human-machine interfaces. The project utilizes spin-based magneto resistors, namely tunneling magneto resistors (TMRs) and giant magneto resistors (GMRs) provided by the French project partner CEA-SPEC as highly sensitive magnetic field sensors that can be implemented in a miniaturized fashion on implantable probes in the form of so-called magnetrodes. Since the magnetic fields associated with neuronal activity are tiny, even very close to their place of origin, the key to reading out such signals is to use highly sensitive sensors with integrated interface electronics in very close proximity in order to minimize pickup noise. Therefore, one central goal of the NeuroTMR project was to research and prototypically design very low-noise readout electronics that can be integrated in standard CMOS and that maximally preserve the intrinsic signal-to-noise ratio (SNR) of the neuronal signals. As a major outcome of the project, this has been achieved by designing a novel current source that can effectively bias resistive sensors with record low noise floors. Moreover, an amplifier chain has been designed and manufactured that, in combination with a biasing circuit built around the new low-noise current source, allows to readout the neuronal signals with minimum SNR degradation. Although the integration of the interface electronics into the magnetrodes could not be completed during the runtime of the project due to delays introduced by the COVID pandemic and the closure of labs and manufacturing sites, all individual components were successfully designed and manufactured, allowing for the completion of the new active magnetrode generation soon after the official project end. For the in vivo testing of the probe, we have optimized the recording environment and applied spike sorting methods to treat the data (electrical and magnetic recordings) free of artifacts. The obtained neural probe is thin, 2-dimensional, integrates electrical recordings, and has demonstrated the possibility of measuring signals in the 400 pT range during in-vivo experiments. The in-vivo experiments performed on a rat’s hippocampus highlight the resistance and the long lasting of the probe in biologic liquids, and also its reduced damage to the brain. Currently, the only actual limitation for magnetrode use in neuroscience is its limit of detection, which leads to the necessity of averaging for neuronal spike detection. Moreover, thanks to their versatility and programmability, the ASICs originating from the NeuroTMR project were also successfully tested in combination TMR sensors for the detection of biomolecules in point-of-care (PoC) diagnostic platforms. Thanks to their small form factor, low price, and excellent performance, the interface electronics originating from the NeuroTMR project can pave the way to widespread use of PoC platforms based on magneto resistors in personalized medicine.

Projektbezogene Publikationen (Auswahl)

 
 

Zusatzinformationen

Textvergrößerung und Kontrastanpassung